Closed-cell foam rubber.

Applications: thermal insulation and soundproofing thermal insulation and soundproofing - liquid- and gas-tight gaskets in doors, windows, etc.
Vibration damping, waterproofing material for industrial applications, generally.

Sizes: thickness ranging from 1.5 to 60 mm - rolls h 1000x10000 mm - sheets 1000x2000 mm
Made-to-measure profiles.

Technical features Unit of measurement Measured values Standards
Composition   CR/NBR  
Reference standard   SCE 42-2C2/SBE 42-2B2 ASTM D-1056
Cell structure   closed-cell  
Colour   black  
Density kg/m3 150±25 ISO 845-88 - ASTM D 3575
Thermal conductivity (samples 100x100x10) W/m.K 0.0384  
Water absorption % 2<5 ASTM D 1056
Service temperature range °C -0.4 ASTM D 1056 p.53-60
Resistance at low temperature test °C (x 16 ore) -40 UNI 7320 - ASTM D 1056
Shrinkage after 7 days at 70 °C % <4 max <5 ASTM D 1204
Tensile strain at break % >250 ASTM D 412
Break strength kg/cm2 11.5 ASTM D 412
Tearing strength kg/cm 4.3 ASTM D 624
Strengths   AIR+U.V.
 VERY GOOD
 
Compressive yield strength at 25% kg/cm2 0.4 ASTM 1056/85
Compression set at 50% % 25 ASTM 1056
22h at ambient temperature
Residual matter test after heating % 32.7 standard VDA 675 130/92
(residual ash at 950 °C)
Solvent extract test (cylohexane/acetone)  % 32.7 standard VDA 675 125/92
Hardness Shore 00 50±5 ASTM D 2240
Immersion in IRM 903 oil (22h at 70 °C) % -18.5 / class B tab. 1 ASTM D-1056/00
(D 471/98)
Fire-resistance rating   UL 94 - HF1 - 2 to 8 mm UL 94
yellow card UL 94 - V0 - 10 to 40 mm
UL 46, sect. 33, and UL 50, sect. 43   pass  
Fire test (m. th. 30 on specimen face)   pass UNI EN ISO 11195-2/05
Oxygen index   29.3 medium Lol ASTM D 2863
STANDARD AFNOR NF-F 16-101/88   GRID 5  
FIRE REACTION CLASS M2
SMOKE CLASSIFICATION F3
SMOKE VALUE 44
ASTM C 542:2005 - ASTM C 1166:2006   CONFORMING (74 mm)  
Vulcanization peroxide   No sulphur